Professional chimney service
Dunlap Chimney Experts

A Fireplace Remodel That Starts With What Is Behind the Brick

Book Fireplace Remodel

Photo Report After Every Visit
A Verdict for Each Part
Prices on a Separate Sheet
NFPA 211 Inspection Levels
Based in Stanton
Photo Report After Every Visit
A Verdict for Each Part
Prices on a Separate Sheet
NFPA 211 Inspection Levels
Based in Stanton

What the Visit Records

A remodel is planned from the report out. We inspect the firebox and flue first, so new stone is not set over a cracked back wall or a damper that leaks. The plan sheet lists the surround material, hearth size, mantel height and clearances, plus any gas line or insert that goes with it. You approve the sheet before work starts, and photos of each stage go into your file.

Firebox and flue inspected before the design is set
Surrounds in stone, tile or plaster
Mantel height and trim distance measured to code
Hearth sized to the opening
Gas line and insert added if you want one

Why we inspect before we design

A remodel covers things up. Once new stone is set over a brick face, nobody sees the cracks in that brick again until they turn into a problem. So we do not design over a fireplace we have not looked at. The first visit is an inspection of the firebox, the damper, the flue and the area around the opening, and its report becomes the base of the plan. Common findings in Orange County remodels: a firebox with open joints that should be reset before the new face goes on; a damper that has seized; a flue that cannot carry the appliance the owner has in mind; a mantel or wall finish that would sit closer to the opening than the rules allow. Finding those first keeps the project honest. The design then works with what the fireplace really is, and nothing has to be torn back out after the stone is up and the room has been painted.

Most remodels fall into a handful of kinds. A refacing keeps the fireplace as it is and changes the face: tile, stone veneer, plaster or new brick over the old. A surround and mantel change swaps the trim around the opening. A hearth change rebuilds or extends the floor in front of the fire. A conversion changes how the fireplace burns, usually by fitting a gas insert or a log set, and often comes with a new face at the same time. Each kind brings its own clearances, materials and weights to plan for. Stone veneer, for example, needs a backing that can carry it and a wall that will not crack under the load. Our written scope lists the kind of work, the materials you pick, the clearance figures that apply and any repair from the inspection that has to happen first, so the plan and the fireplace agree before anyone orders stone.

Factory-built units and the written scope

Many houses and condos around Stanton, Cypress and Tustin built from the 1970s on have a factory-built fireplace: a steel unit with its own metal chimney, framed in and finished to look like masonry. These can be remodeled, but within rules the original maker set. The face, the hearth and the mantel all have listed clearances, and some units do not allow certain materials close to the opening, or anything that blocks the air grilles above and below the box. We find the maker's label, usually inside the unit, and plan to its numbers. If the unit is old enough that its parts are no longer sold, or its panels are cracked, a remodel is often the moment to replace it with a new unit or a gas insert listed for that kind of box. The report lays out those options with their costs side by side so the look and the safety are planned together.

We write the remodel as one scope with separate lines: the repairs from the inspection, demolition, any new firebox or insert, the face, the hearth and the mantel. You can see what each piece adds and drop or change any line before signing. The only published prices that touch a remodel are the gas appliances. Converting the current opening with a gas insert costs $2,650 to $5,300 installed, and a vented gas unit on an outside wall with no chimney behind it costs $4,200 to $8,450. Everything else is priced from the measured plan. Timing depends on materials; stone and custom mantels can take a while to arrive, and the start date is set once they are in hand. To begin, use the contact form and tell us what the fireplace is now and what you dislike about it. The first visit is the inspection the plan is built on.

What You Hold Afterward

Dated Record

Address, date and the parts examined, kept on file

Plain Verdicts

Sound, watch or repair beside every item

Separate Price Sheet

Repairs listed one per line, away from the findings

Photos Throughout

A picture behind each note, before and after any work

Related Work

Chimney Sweep

Soot and glaze brushed out of the flue, then photos of the bare tile and a short note on what the brushing uncovered.

Details →

Chimney Inspection

NFPA 211 Level 1, 2 or 3 checks, delivered as a written report with labelled photos and a verdict for each part.

Details →

Chimney Repair

Repairs taken straight from the report, with each photographed defect given its own fix and its own price line.

Details →

Fireplace Inspection

Firebox, damper, hearth and surround examined from inside the room, with a photo page you keep.

Details →

Fireplace Repair

Firebox, damper and hearth faults from your report fixed, with photos of each repair added to the same file.

Details →

Chimney Level 2 Inspection

Recorded video of the flue interior plus attic and roof checks, written up for a sale, a new appliance or storm damage.

Details →

Chimney Cap Installation

A fitted top that stops rain and animals getting into the flue and embers getting out, photographed once it is on.

Details →

Chimney Flashing Repair

Metal at the roof line photographed and replaced where it has lifted, rusted or been patched over with tar.

Details →

Chimney Masonry Repair

Brick and mortar faults from the report fixed in a mortar matched to the age and hardness of your brick.

Details →

Chimney Rebuilds

Chimneys too loose to repair taken down and laid up again, with each stage photographed for your records.

Details →

Fireplace Cleaning

Ash, soot and old buildup cleared from the firebox and doors, with notes on anything the cleaning uncovers.

Details →

Gas Fireplace Cleaning

Burner, pilot, logs and glass cleaned on a gas unit, with a written note on the vent and the flame.

Details →

Gas Fireplace Repair

Gas units that misfire, lose the pilot or refuse to ignite tested part by part, with the results written down.

Details →

Fireplace Inserts

A gas or wood insert set into your existing opening with its own liner, documented from measuring to final test.

Details →

Pellet Stove Repair

A pellet stove that quits mid-burn or never catches, tested one part at a time and written up on a service sheet.

Details →

Wood Stove Repair

Worn gaskets, baffles, firebrick and pipe on a wood stove replaced, after a check that lists every worn part.

Details →

Gas Logs

A gas log set chosen for your firebox and room, installed with a leak test and a written record of the setup.

Details →

Chimney Seismic Retrofit

Brick chimneys assessed for quake risk, then braced, strapped or rebuilt lighter, with the plan and photos in writing.

Details →

Chimney Crown Repair

Crown cracks photographed and measured, then sealed if they are shallow or recast if they run right through.

Details →

Dryer Vent Cleaning

Lint cleared from the dryer duct to the outside hood, with airflow noted before and after on a short sheet.

Details →

Chimney Liner Installation

A new stainless liner run through a cracked or oversized flue, with video before and after for your file.

Details →

Chimney Leak Repair

Water coming in at the chimney traced to where it enters, then repaired, with each entry point priced on its own line.

Details →

Chimney Waterproofing

A vapor-open repellent for brick that is already sound, so the face takes in less rain through a wet winter.

Details →

Chimney Damper Repair

Dampers that stick, rattle or leave a gap freed, repaired or replaced, with the fault noted in your report.

Details →

Chimney Chase Cover

The metal top on a framed chimney photographed and replaced when it has rusted, sagged or split at the seams.

Details →