What the Visit Records

Several parts can stop a pellet stove: the feed motor, the igniter, the blowers, the sensors and the control board. We test each one and write the readings down, so you see which part failed and why. Swollen pellets and ash packed in the burn pot are common culprits, and we clear them on the visit. The vent from the stove to the outside is looked at too.

Feed motor and auger tested for jams
Igniter resistance measured
Blowers cleaned and run under load
Sensors and safety switches tested
Vent run inspected from stove to outside

How a pellet stove stops working

A pellet stove is a set of parts that have to work in a fixed order. Pellets drop from the storage bin into a screw that carries them to the burn pot; an electric igniter heats air until they catch; one fan supplies air to the fire and pulls exhaust out; a second blows room air over the hot surfaces; and a set of switches and sensors tells the board whether it is safe to keep going. Any one of those parts can stop the stove on its own. A sensor reading too hot shuts it down. A pressure switch that sees weak draft shuts it down. A jammed screw starves the fire until it goes out. The result in the room often looks the same: a stove that quits partway through the evening. Finding which link broke takes testing rather than guessing, and the testing is what the visit is built around from the moment we arrive.

We start with what the stove tells us. Most models store or display a fault code, and we write it down. Then we work through the parts with the stove cold and then running: the feed motor and screw for binding or a sheared pin, the igniter's draw on a meter, the fans for speed and bearing noise, the switches for continuity, and the door and bin seals for air leaks that upset the draft. Each reading goes on the service sheet. The sheet ends with the cause we found, the part or parts that fix it, their price and whether the stove can safely run until they arrive. If the control board is at fault, the sheet shows how we ruled out the cheaper parts first, since the board is the costliest item on most stoves and swapping it on a hunch is an expensive way to find out a small switch was to blame.

Ash, the vent and the yearly service

Most pellet stove faults we see are caused or helped along by ash. Pellets leave a fine ash that collects in the burn pot, in the passages behind the firebox and in the exhaust pipe. A burn pot with clogged holes starves the fire of air and leaves hard clinkers. Ash packed in the exhaust passages weakens the draft until the pressure switch shuts the stove off. Ash in the vent pipe, especially at the tee and along any level run, does the same and can let exhaust into the house. A yearly service opens the stove far enough to clean all of those, checks the seals and vacuums the fans. It is also when we look at the vent where it leaves the house: the wall or roof end, its distance from windows and doors, and any pipe joint that has come loose. Those findings go on the same sheet as the repair work, so the stove has one record.

Two things outside the stove cause a lot of calls. The first is fuel. Pellets that have drawn moisture in a damp garage swell and crumble into dust that jams the feed and burns poorly, and a bag of fresh, dry pellets often settles a fault that comes and goes. The second is power. A pellet stove needs electricity to run, and a surge or an outage mid-burn can leave the board confused or the stove full of unburned fuel. We note both on the sheet when they play a part. To book, use the contact form and describe what the stove does from the moment you press start until it stops, plus any code on the display, and the maker's name if you have it. The fault decides the work, so the price arrives on the written sheet once testing is done, and the yearly service can be added to the same visit.

What You Hold Afterward

Dated Record

Address, date and the parts examined, kept on file

Plain Verdicts

Sound, watch or repair beside every item

Separate Price Sheet

Repairs listed one per line, away from the findings

Photos Throughout

A picture behind each note, before and after any work

Related Work

Chimney Sweep

Soot and glaze brushed out of the flue, then photos of the bare tile and a short note on what the brushing uncovered.

Details →

Chimney Inspection

NFPA 211 Level 1, 2 or 3 checks, delivered as a written report with labelled photos and a verdict for each part.

Details →

Chimney Repair

Repairs taken straight from the report, with each photographed defect given its own fix and its own price line.

Details →

Fireplace Inspection

Firebox, damper, hearth and surround examined from inside the room, with a photo page you keep.

Details →

Fireplace Repair

Firebox, damper and hearth faults from your report fixed, with photos of each repair added to the same file.

Details →

Chimney Level 2 Inspection

Recorded video of the flue interior plus attic and roof checks, written up for a sale, a new appliance or storm damage.

Details →

Chimney Cap Installation

A fitted top that stops rain and animals getting into the flue and embers getting out, photographed once it is on.

Details →

Chimney Flashing Repair

Metal at the roof line photographed and replaced where it has lifted, rusted or been patched over with tar.

Details →

Chimney Masonry Repair

Brick and mortar faults from the report fixed in a mortar matched to the age and hardness of your brick.

Details →

Chimney Rebuilds

Chimneys too loose to repair taken down and laid up again, with each stage photographed for your records.

Details →

Fireplace Cleaning

Ash, soot and old buildup cleared from the firebox and doors, with notes on anything the cleaning uncovers.

Details →

Gas Fireplace Cleaning

Burner, pilot, logs and glass cleaned on a gas unit, with a written note on the vent and the flame.

Details →

Gas Fireplace Repair

Gas units that misfire, lose the pilot or refuse to ignite tested part by part, with the results written down.

Details →

Fireplace Remodel

A new face, hearth or mantel planned around a chimney we have already inspected and written up.

Details →

Fireplace Inserts

A gas or wood insert set into your existing opening with its own liner, documented from measuring to final test.

Details →

Wood Stove Repair

Worn gaskets, baffles, firebrick and pipe on a wood stove replaced, after a check that lists every worn part.

Details →

Gas Logs

A gas log set chosen for your firebox and room, installed with a leak test and a written record of the setup.

Details →

Chimney Seismic Retrofit

Brick chimneys assessed for quake risk, then braced, strapped or rebuilt lighter, with the plan and photos in writing.

Details →

Chimney Crown Repair

Crown cracks photographed and measured, then sealed if they are shallow or recast if they run right through.

Details →

Dryer Vent Cleaning

Lint cleared from the dryer duct to the outside hood, with airflow noted before and after on a short sheet.

Details →

Chimney Liner Installation

A new stainless liner run through a cracked or oversized flue, with video before and after for your file.

Details →

Chimney Leak Repair

Water coming in at the chimney traced to where it enters, then repaired, with each entry point priced on its own line.

Details →

Chimney Waterproofing

A vapor-open repellent for brick that is already sound, so the face takes in less rain through a wet winter.

Details →

Chimney Damper Repair

Dampers that stick, rattle or leave a gap freed, repaired or replaced, with the fault noted in your report.

Details →

Chimney Chase Cover

The metal top on a framed chimney photographed and replaced when it has rusted, sagged or split at the seams.

Details →
Call (657) 233-4468